This device has features like Online power management, real-time power efficiency monitoring, real-time monitoring of electrical circuit parameter (voltage, current, power KWH, etc), and are reported, which help identify where energy savings are required, and further save power bills through analysis of collected data, power consumption analysis.

 

Technical Specification of Power Supply Module

Power supply module will offer stable DC power for smart breaker MTS3 and owns class II surge protection. It is also the necessary part for smart breaker MTS3 system.
Item Code MTS3-P25 MTS3-P25D
Standards EN55022, EN55024, EN61000, EN60950, GB4943
Approvals CE, CCC
Functions (Vac) Power Supplier, surge Protection
Rated Voltage Ue (Vac) 220
Rated Input Voltage Range (Hz) 100-265
Frequency (HZ) (mA) 50/60
Rated Input Current (Vac) 350
Rated Output Voltage (A) 12
Rated Output Current 2.5
Type / Test Class of Surge Protection (mm) 2 / II
Numbers of Modules ( 1 module=18mm) (KA) 36 (2P)
Max. Discharge Current Imax (8/20) per pole Imax (KA) 15
Nominal Discharge Current In (8/20) per pole In 10
Max. Working Capacity (Max.numbers of breakers) (mm²) 10*(iRCBO/ iMCB)
Conductor Cross-sections (mm²) 38
Pollution Degree 2
Ambient Temperature (ºC) -15 - +40
Storage Temperature (ºC) -25 - +70
Humidity < 95%
Altitude <=2000
Terminal Connection Cable / Pin-type busbar
Mounting  Din rail En60715(35mm) by means of fast clip device
Connection Both from top to bottom or reverse

 

 

Technical Specification of iRCBO

Power supply module will offer stable DC power for smart breaker MTS3 and owns class II surge protection. It is also the necessary part for smart breaker MTS3 system.
Item Code MTS3-R2 MTS3-R4
Standards IEC61009.1, GB16917.1
Approvals CE, CCC
Approvals 2P 4P
Rated Voltage Ue (Vac) 230 400
Frequency (HZ) (mA) 50/60
Rated Current (A) 16,20,25,32,40,50,63,80
Type (wave form of the earth leakage sensed) (mA) AC
Rated Resdiual Current (I∆n) (Vac) 30
Rated Insulation Voltage Ui (A) 500
Rated Breaking Capacity acc.to IEC61009 Ultimate Icn 6000
Breaking Time Under I∆n <=0.1 S
Breaking Time Under Icn <=0.04S
Tripping Characteristic C (5-10In)
Other Functions
Over /under voltage protection, warning and alarm
Max. power and current setting
Auto test of earth leakage current
High temperature protection, warning and alarm
Arcing fault protection, warning and alarm
Monitor of current, power, voltage in real-time
Remote control
Timer
Meter
Event record and notice
Breaking time when voltage is over 265Vac 10s
Over / Under Voltage Warning Voltage is higher than 250Vac or lower than 190Vac
Breaking time when the current reach the 5s
Max.current or power setup the time for switching on automatically after 5s
Auto-test of earth leakage current (mA) 30,50,100,1000(adjustable)
Max. Working Capacity (Max.numbers of breakers) (mm²) 29*(iRCBO/ iMCB)
Electric Life (Times) 10000
Mechanical Life (Times) 20000
Conductor Cross-sections (mm²) 38
Protection Degree 2
Numbers of modules (1 module=18mm) 3 (54mm) 5(90mm)
Ambient Temperature (ºC) -15 - +40
Storage Temperature (ºC) -25 - +70
Humidity < 95%
Altitude <=2000
Terminal Connection Cable/Pin-type busbar
Mounting Din rail En60715(35mm) by means of fast clip device
Connection Both from top to bottom or reverse

 

 

Technical Specification of iMCB

Smart Breakers are the core part of MTS3 smart system,it combine protection, metering, monitor, timer,automation, event record and notice.
Item Code MTS3-M1 MTS3-M2 MTS3-M3 MTS3-M4
Standards IEC60898, GB10963.1
Approvals CE, CCC
Poles 1P 2P 3P 4P
Rated Voltage Ue (Vac) 230/400-240/415
Operational Voltage (Vac) Min.90  Max:250/440
Frequency (HZ) 50 / 60
Rated Current (A) 10,16, 20, 25, 32, 40, 50, 63, 80
Rated insulation voltage Ui (Vac) 500
Rated Impulse Withstand Voltage (1.2/50) Uimp (Vac) 2500
Rated Breaking Capacity Acc.to IEC60899 Icn (A) 6000
Breaking Time Under Icn <=0.04S
Tripping Characteristic B (3-5In), C (5-10In), D (10-14In)
Other Functions
Over /under voltage protection , warning and Alarm
Max. Power and Current Setting
Auto test of earth leakage current
High Temperature protection, warning and Alarm
Arcing Fault Protection, warning and Alarm
Monitor of Current, power, voltage in real-time
Remote control
Timer
Meter
Event record and notice
Breaking time  when voltage is over 263Vac 10S
Over / Undder Voltage Warning when voltage is higher than 250Vac or lower than 190Vac
Breaking time when the current reach the max.current or power setup 5s
Electric Life (Times) 10000
Mechanical Life (Times) 20000
Conductor Cross-sections (mm²) 38
Pollution Degree 2
Numbers of Modules ( 1 module=18mm) 1.5 (27mm) 2.5 (45mm) 4 (72mm) 5 (90mm)
Ambient Temperature (ºC) -15 - +40
Storage Temperature (ºC) -25 - +70
Humidity  < 95%
Altitude <=2000
Terminal Connection Cable/Pin-type busbar
Mounting  Din rail En60715(35mm) by means of fast clip device
Connection Both from top to bottom or reverse

 

 

Technical Specification of Communicaiton Module

Communication module includes wireless and wired mechanism's. It also functions as hotspot.
Order Code MTS3-C
Product Code S3-T30/RS485/WIFI/4G/Ethernet
Standards EN301489, EN300328, EN62479, EN60950
Approvals CE, CCC
Types (Vdc) S3-T30/RS485/WIFI/4G/Ethernet
Rated Input Voltage 12
Numbers of modules (1 module=18mm) 1 (18mm)
Max. working capacity ( Max.numbers of breaker powering) (mm²) 16, 20, 25, 32, 40, 50, 63, 80
Type (wave form of the earth leakage sensed) (iRCBO+ iMCB) x 32pcs
Conductor Cross-sections 2
Ambient Temperature (ºC) -15 - +40
Storage Temperature (ºC) -25 - +70
Humidity < 95%
Altitude <=2000
Terminal Connection Cable / Pin-type busbar
Mounting Din rail EN60715(35mm) by means of fast clip
Connection Both from top to bottom or reverse